On inconsistencies in the work of P Maraner (reply to comment [Usp. Fiz. Nauk 186 793 2016] to the paper "Quadratic Sagnac effect — the influence of gravitational potential of Coriolis force on the phase difference between the arms of a rotating Michelson interferometer (an explanation of D C Miller's experimental results, 1921—1926)" (Usp. Fiz. Nauk 185 431 (2015) [Phys. Usp. 58 398 (2015)])a Federal Research Center A.V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences, ul. Ulyanova 46, Nizhny Novgorod, 603000, Russian Federation b Institute of Microstructure Physics, Russian Academy of Sciences, ul. Ulyanova 46, Nizhnii Novgorod, 603600, Russian Federation We consider the distributions of the scalar gravitational potential of Coriolis forces in different parts of the shoulder rotating equal-arms Michelson interferometer. It results in view of the very small difference between the phase of light in the shoulders of the Michelson interferometer, in comparison with the phase difference due to the quadratic Sagnac effect. It has been shown that it is there is an effect discussed earlier by P. Maraner, which is higher approximation quadratic Sagnac effect.
|
||||||||||||||||||
|