Issues

 / 

2008

 / 

January

  

Instruments and methods of investigation


Electron emission from ferroelectric plasma cathodes


Lebedev Physical Institute, Russian Academy of Sciences, Leninsky prosp. 53, Moscow, 119991, Russian Federation

Recent and not so recent experimental data are analyzed to show that the reason for strong electron emission from dielectric cathodes is the incomplete discharge occurring on the dielectric surface due to the electric field there being tangentially nonzero. The places of origin of such discharges are the metal-dielectric-vacuum triple junctions (TJs). As the discharge plasma moves over the surface of the dielectric electrode, the bias current arises, and an electric microexplosion occurs at a TJ. If the number of TJs is large, as it is for a metal grid held tightly to a ferroelectric, electron currents of up to 104 A with densities of more than 102 A cm-2 can be achieved. A surface discharge is initiated by applying a triggering pulse to the metal substrate deposited beforehand onto the opposite side of the ferroelectric. If this pulse leads the accelerating voltage pulse, the electron current is many times the Child-Langmuir current. The reason for the ferroelectric effect is the large permittivity (ε > 103) of the materials used (BaTiO3, PLZT, PZT). Although these devices have come to be known as ferroelectric cathodes, we believe ferroelectric plasma cathodes would be a better term to use to emphasize the key role of plasma effects.

Fulltext pdf (447 KB)
Fulltext is also available at DOI: 10.1070/PU2008v051n01ABEH006426
PACS: 52.80.−s, 84.70.+p, 85.45.−w (all)
DOI: 10.1070/PU2008v051n01ABEH006426
URL: https://ufn.ru/en/articles/2008/1/e/
000256193500005
2-s2.0-43949144229
2008PhyU...51...79M
Citation: Mesyats G A "Electron emission from ferroelectric plasma cathodes" Phys. Usp. 51 79–100 (2008)
BibTexBibNote ® (generic)BibNote ® (RIS)MedlineRefWorks

Оригинал: Месяц Г А «Электронная эмиссия из сегнетоэлектрических плазменных катодов» УФН 178 85–108 (2008); DOI: 10.3367/UFNr.0178.200801e.0085

References (101) Cited by (26) ↓ Similar articles (5)

  1. Stepanov A V, Konusov F V et al Nuclear Instruments And Methods In Physics Research Section A: Accelerators, Spectrometers, Detectors And Associated Equipment 1062 169223 (2024)
  2. Jmerik V, Nechaev D et al Nanomaterials 13 1077 (2023)
  3. Bobrov M S, Hrebtov M Y, Yudin P V J. Phys.: Conf. Ser. 2119 012124 (2021)
  4. Jmerik V, Nechaev D et al Nanomaterials 11 2553 (2021)
  5. Hrebtov M Yu, Bobrov M S J. Phys.: Conf. Ser. 1677 012134 (2020)
  6. Shalenov E O, Dzhumagulova K N et al J. Phys.: Conf. Ser. 1697 012209 (2020)
  7. Liu Ya, Xu X et al Pramana - J Phys 92 (4) (2019)
  8. Mesyats G A Russ Phys J 61 807 (2018)
  9. Andrianov V A, Bush A A et al J. Synch. Investig. 11 704 (2017)
  10. Orbach Ya, Nissan T et al IEEE Trans. Electron Devices 63 2156 (2016)
  11. Stepanov A D, Gilson E P et al 23 (4) (2016)
  12. Hang T, Glaum Ju et al Acta Materialia 102 284 (2016)
  13. Khasanshin R H, Novikov L S, Korovin S B J. Synch. Investig. 10 1001 (2016)
  14. Darinskii B M, Lazarev A P, Sigov A S Phys. Solid State 57 1160 (2015)
  15. Janus H W, Halenka J, Biedrzycki K J. Phys. D: Appl. Phys. 47 305202 (2014)
  16. Hutsel B T, Kovaleski S D et al IEEE Trans. Plasma Sci. 41 99 (2013)
  17. Einat M, Pilossof M et al Phys. Rev. Lett. 109 (18) (2012)
  18. Ben-Moshe R, Einat M 98 (17) (2011)
  19. Konieczna B, Biedrzycki K et al Ferroelectrics 417 33 (2011)
  20. Korobkin Yu V, Gorbunov S P et al Tech. Phys. Lett. 36 447 (2010)
  21. Gurovich V T, Krasik Ya E et al 106 (5) (2009)
  22. Vekselman V, Gleizer J et al Physics Of Plasmas 16 113504 (2009)
  23. Yarmolich D, Vekselman V et al IEEE Trans. Plasma Sci. 37 1261 (2009)
  24. YUN YE, TAILIANG GUO Integrated Ferroelectrics 107 105 (2009)
  25. Kushnir V A, Khodak I V Instrum Exp Tech 51 729 (2008)
  26. Yarmolich D, Vekselman V et al Plasma Sources Sci. Technol. 17 035002 (2008)

© 1918–2024 Uspekhi Fizicheskikh Nauk
Email: ufn@ufn.ru Editorial office contacts About the journal Terms and conditions